• Users Online: 1055
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 33  |  Issue : 2  |  Page : 69-74

Evaluation of microcrack formation after root-end preparation with two different types of ultrasonic retrotips and conventional bur: A stereomicroscopic study


Department of Conservative and Endodontics, M.P. Dental College and Hospital, Vadodara, Gujarat, India

Correspondence Address:
Dr. Sonali Vinod Kapoor
30 Nirman Society, Alkapuri, Vadodara - 390 007, Gujarat
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/endo.endo_42_21

Rights and Permissions

Introduction: The aim of this in vitro study is to evaluate and compare the root-end cavities for the presence of microcracks after cavity preparation using two different ultrasonic (US) retrotips and conventional bur. Materials and Method: Thirty single-rooted teeth were instrumented and obturated. Three millimeters of apices were resected. Retrograde Class I cavities 3 mm deep were prepared on resected surfaces of ten teeth with diamond-coated US retrotip (Group 1), ten teeth with zirconium-nitride-coated US retrotip (Group 2), and ten teeth with conventional bur (Group 3). The root-end surfaces were examined under a stereomicroscope and the resected root surfaces were evaluated for the presence of microcracks on microphotographs. Results: Statistically significant difference was detected between diamond-coated and zirconium-nitride-coated US retrotips and also significant difference was detected when the same were compared with conventional bur for the presence of microcracks. Conclusion: Within the limitations of the study, it can be concluded that both zirconium-nitride- and diamond-coated retrotips produce more dentinal crack formation compared to conventional bur, but none of them produce a complete crack. Moreover, the diamond-coated retrotips produce less debris formation and minimal dentinal crack compared to zirconium-nitride-coated retrotips.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed779    
    Printed6    
    Emailed0    
    PDF Downloaded91    
    Comments [Add]    

Recommend this journal