ORIGINAL ARTICLE
Year : 2021 | Volume
: 33 | Issue : 2 | Page : 69--74
Evaluation of microcrack formation after root-end preparation with two different types of ultrasonic retrotips and conventional bur: A stereomicroscopic study
Dilshad Kersi Mandviwala, Vineet Suresh Agrawal, Sonali Vinod Kapoor Department of Conservative and Endodontics, M.P. Dental College and Hospital, Vadodara, Gujarat, India
Correspondence Address:
Dr. Sonali Vinod Kapoor 30 Nirman Society, Alkapuri, Vadodara - 390 007, Gujarat India
Introduction: The aim of this in vitro study is to evaluate and compare the root-end cavities for the presence of microcracks after cavity preparation using two different ultrasonic (US) retrotips and conventional bur.
Materials and Method: Thirty single-rooted teeth were instrumented and obturated. Three millimeters of apices were resected. Retrograde Class I cavities 3 mm deep were prepared on resected surfaces of ten teeth with diamond-coated US retrotip (Group 1), ten teeth with zirconium-nitride-coated US retrotip (Group 2), and ten teeth with conventional bur (Group 3). The root-end surfaces were examined under a stereomicroscope and the resected root surfaces were evaluated for the presence of microcracks on microphotographs.
Results: Statistically significant difference was detected between diamond-coated and zirconium-nitride-coated US retrotips and also significant difference was detected when the same were compared with conventional bur for the presence of microcracks.
Conclusion: Within the limitations of the study, it can be concluded that both zirconium-nitride- and diamond-coated retrotips produce more dentinal crack formation compared to conventional bur, but none of them produce a complete crack. Moreover, the diamond-coated retrotips produce less debris formation and minimal dentinal crack compared to zirconium-nitride-coated retrotips.
How to cite this article:
Mandviwala DK, Agrawal VS, Kapoor SV. Evaluation of microcrack formation after root-end preparation with two different types of ultrasonic retrotips and conventional bur: A stereomicroscopic study.Endodontology 2021;33:69-74
|
How to cite this URL:
Mandviwala DK, Agrawal VS, Kapoor SV. Evaluation of microcrack formation after root-end preparation with two different types of ultrasonic retrotips and conventional bur: A stereomicroscopic study. Endodontology [serial online] 2021 [cited 2022 Aug 12 ];33:69-74
Available from: https://www.endodontologyonweb.org/article.asp?issn=0970-7212;year=2021;volume=33;issue=2;spage=69;epage=74;aulast=Mandviwala;type=0 |
|
|